Advanced Oil Detection Technology

Gamma Ray CCL Temp

The Gamma Ray / Collar Locator / Temperature Tool (GCT) integrates three essential downhole measurements in a single tool. It provides gamma ray detection for formation evaluation, collar locator signals for depth correlation, and accurate temperature logging with a fast-response platinum RTD sensor. Designed for real-time or memory operations with the Fast Hybrid Telemetry Tool (FHT), the GCT ensures reliable data acquisition in multiple wellbore conditions.

ENGRD Fullbore Spinner
Injection Flow
Production Flow
Electronics Housing
Three-arm Spinner
Spring-Loaded Cage
Voltage
+18 VDC
Temperature Range
+50°C / 260°C
Depth Resolution
6' typical
Technical Excellence

Gamma Ray / CCL / Temperature Tool (GCT)

The Gamma Ray / Collar Locator / Temperature Tool (GCT) integrates three essential downhole measurements into one tool, providing gamma ray detection, collar locator depth correlation, and accurate downhole temperature logging with a platinum RTD sensor. Compatible with the Fast Hybrid Telemetry Tool (FHT) for real-time or memory operations.

Triple Measurement

Gamma Ray, Collar Locator, and Temperature in a single consolidated tool.

Real-Time & Memory Ready

Fully compatible with Fast Hybrid Telemetry Tool (FHT) for both operating modes.

High Resolution Logging

Precise depth correlation and accurate downhole temperature acquisition.

Gamma Ray

Operating Voltage+18 VDC
Current Draw10 mA
Depth Resolution6' typical
HV Power Supply700–1800 VDC

Temperature Tool (RTD)

Operating Voltage+18 VDC
Current Draw10 mA
Resolution0.15°C
Max Range+50°C to 260°C

Collar Locator (CCL)

Operating Voltage+18 VDC
Current Draw10 mA
Sensitivity1 mV
GainSurface Controlled