The Gamma Ray / Collar Locator / Temperature Tool (GCT) integrates three essential downhole measurements in a single tool. It provides gamma ray detection for formation evaluation, collar locator signals for depth correlation, and accurate temperature logging with a fast-response platinum RTD sensor. Designed for real-time or memory operations with the Fast Hybrid Telemetry Tool (FHT), the GCT ensures reliable data acquisition in multiple wellbore conditions.

ENGRD Fullbore Spinner
→
Injection Flow
→
Production Flow
Electronics Housing
Three-arm Spinner
Spring-Loaded Cage
Voltage
+18 VDC
Temperature Range
122°F – 500°F (50°C – 260°C)
Depth Resolution
6' typical
Technical Excellence

Gamma Ray / CCL / Temperature Tool (GCT)

The Gamma Ray / Collar Locator / Temperature Tool (GCT) integrates three essential downhole measurements into one tool, providing gamma ray detection, collar locator depth correlation, and accurate downhole temperature logging with a platinum RTD sensor. Compatible with the Fast Hybrid Telemetry Tool (FHT) for real-time or memory operations.

Triple Measurement

Gamma Ray, Collar Locator, and Temperature in a single consolidated tool.

Real-Time & Memory Ready

Fully compatible with Fast Hybrid Telemetry Tool (FHT) for both operating modes.

High Resolution Logging

Precise depth correlation and accurate downhole temperature acquisition.

Gamma Ray

Operating Voltage+18 VDC
Current Draw10 mA
Depth Resolution6' typical
HV Power Supply700–1800 VDC

Temperature Tool (RTD)

Operating Voltage+18 VDC
Current Draw10 mA
Resolution0.15°C
Max Range+50°C to 260°C

Collar Locator (CCL)

Operating Voltage+18 VDC
Current Draw10 mA
Sensitivity1 mV
GainSurface Controlled